Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
1.
J Matern Fetal Neonatal Med ; 37(1): 2323623, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38443062

RESUMO

OBJECTIVE: To describe international surveillance and treatment strategies for managing anti-SSA/Ro autoantibody positive pregnancies. STUDY DESIGN: An electronic REDCap questionnaire was distributed to Fetal Heart Society and North American Fetal Therapy Network members which queried institution-based risk stratification, surveillance methods/frequency, conduction abnormality treatments, and postnatal anti-SSA/Ro pregnancy assessment. RESULTS: 101 responses from 59 centers (59% US, 17% international) were collected. Most (79%) do not risk stratify pregnancies by anti-SSA/Ro titer; those that do use varied cutoff values. Many pregnant rheumatology patients are monitored for cardiac abnormalities regardless of maternal anti-SSA/Ro status. Surveillance strategies were based on maternal factors (anti-SSA/Ro status 85%, titer 25%, prior affected child 79%) and monitoring durations varied. Most respondents treat 2° and 3° fetal atrioventricular block, commonly with dexamethasone and/or IVIG. CONCLUSIONS: Wide variation exists in current fetal cardiac surveillance and treatment for anti-SSA/Ro autoantibody positive pregnancies, highlighting the need for evidence-based protocols to optimize care.


Assuntos
Bloqueio Atrioventricular , Criança , Feminino , Gravidez , Humanos , Autoanticorpos , Coração Fetal , Instalações de Saúde , Cuidado Pré-Natal , Vitaminas
2.
Circulation ; 149(10): e937-e952, 2024 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-38314551

RESUMO

Disorders of the cardiac rhythm may occur in both the fetus and neonate. Because of the immature myocardium, the hemodynamic consequences of either bradyarrhythmias or tachyarrhythmias may be far more significant than in mature physiological states. Treatment options are limited in the fetus and neonate because of limited vascular access, patient size, and the significant risk/benefit ratio of any intervention. In addition, exposure of the fetus or neonate to either persistent arrhythmias or antiarrhythmic medications may have yet-to-be-determined long-term developmental consequences. This scientific statement discusses the mechanism of arrhythmias, pharmacological treatment options, and distinct aspects of pharmacokinetics for the fetus and neonate. From the available current data, subjects of apparent consistency/consensus are presented, as well as future directions for research in terms of aspects of care for which evidence has not been established.


Assuntos
American Heart Association , Arritmias Cardíacas , Recém-Nascido , Estados Unidos , Criança , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamento farmacológico , Taquicardia , Feto , Eletrofisiologia
3.
Pediatr Cardiol ; 45(4): 722-728, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38411710

RESUMO

Pulmonary balloon valvuloplasty (PBV) is the treatment of choice for subjects with isolated pulmonary valve stenosis (IPS). The purpose of this study was to define fetal echocardiographic features associated with an inpatient PBV prior to newborn hospital discharge and characterize resource utilization of IPS fetuses among participating centers. Six center, retrospective case series of singleton fetuses identified between 2010 and 2020 with IPS. Third-trimester echocardiogram data was compared with postnatal data, included pulmonary valve Doppler velocities, pulmonary valve insufficiency and ductus arteriosus flow direction. Comparison between subjects who underwent inpatient PBV during their newborn hospital admission versus those infants referred for outpatient PBV after initial hospital discharge. We analyzed data by logistic regression, student t test and Chi-Square testing with a p value of ≤ 0.05 considered statistically significant. Forty-nine IPS fetuses were identified. Thirty-eight (78%) underwent inpatient PBV at 5 (range 1-58) days and 11 (22%) underwent outpatient PBV at 51.8 (11-174) days. Newborns requiring an inpatient PBV were more likely to have one or more characteristics on 3rd-trimester fetal echocardiogram: left to right or bidirectional ductus arteriosus flow (61% vs 0%), and/or a peak pulmonary valve velocity > 3.0 m/s (odds ratio 16.9, 95% confidence interval 3.02-94.17) with a sensitivity of 90.4% and specificity of 97.7%. Ductus arteriosus flow direction and pulmonary valve peak velocity in the 3rd trimester can successfully predict the need for newborn inpatient PBV. We speculate these findings may be useful in choosing delivery site for the pregnancy complicated by fetal IPS.


Assuntos
Valvuloplastia com Balão , Permeabilidade do Canal Arterial , Canal Arterial , Estenose da Valva Pulmonar , Lactente , Feminino , Gravidez , Humanos , Recém-Nascido , Estudos Retrospectivos , Ecocardiografia , Terceiro Trimestre da Gravidez , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Ultrassonografia Pré-Natal
5.
Arthritis Rheumatol ; 76(3): 411-420, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37947364

RESUMO

OBJECTIVE: This prospective study of pregnant patients, Surveillance To Prevent AV Block Likely to Occur Quickly (STOP BLOQ), addresses the impact of anti-SSA/Ro titers and utility of ambulatory monitoring in the detection of fetal second-degree atrioventricular block (AVB). METHODS: Women with anti-SSA/Ro autoantibodies by commercial testing were stratified into high and low anti-52-kD and/or 60-kD SSA/Ro titers applying at-risk thresholds defined by previous evaluation of AVB pregnancies. The high-titer group performed fetal heart rate and rhythm monitoring (FHRM) thrice daily and weekly/biweekly echocardiography from 17-26 weeks. Abnormal FHRM prompted urgent echocardiography to identify AVB. RESULTS: Anti-52-kD and/or 60-kD SSA/Ro met thresholds for monitoring in 261 of 413 participants (63%); for those, AVB frequency was 3.8%. No cases occurred with low titers. The incidence of AVB increased with higher levels, reaching 7.7% for those in the top quartile for anti-60-kD SSA/Ro, which increased to 27.3% in those with a previous child who had AVB. Based on levels from 15 participants with paired samples from both an AVB and a non-AVB pregnancy, healthy pregnancies were not explained by decreased titers. FHRM was considered abnormal in 45 of 30,920 recordings, 10 confirmed AVB by urgent echocardiogram, 7 being second-degree AVB, all <12 hours from normal FHRM and within another 0.75 to 4 hours to echocardiogram. The one participant with second/third-degree and two participants with third-degree AVB were diagnosed by urgent echocardiogram >17 to 72 hours from an FHRM. Surveillance echocardiograms detected no AVB when the preceding interval FHRM recordings were normal. CONCLUSION: High-titer antibodies are associated with an increased incidence of AVB. Anti-SSA/Ro titers remain stable over time and do not explain the discordant recurrence rates, suggesting that other factors are required. Fetal heart rate and rhythm (FHRM) with results confirmed by a pediatric cardiologist reliably detects conduction abnormalities, which may reduce the need for serial echocardiograms.


Assuntos
Bloqueio Atrioventricular , Complicações na Gravidez , Criança , Gravidez , Humanos , Feminino , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Autoanticorpos , Estudos Prospectivos , Anticorpos Antinucleares , Ecocardiografia/métodos
6.
JACC Case Rep ; 27: 102110, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38094730

RESUMO

A 32-week fetus with tachycardia and bradycardia, diagnosed with torsades de pointes, atrioventricular block, and sinus bradycardia due to a de novo KCNH2 mutation was successfully managed by a cardio-obstetrical team. Maternal/fetal pharmacogenomic testing resulted in appropriate drug dosing without toxicity and delivery of a term infant in sinus rhythm.

7.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37975542

RESUMO

AIMS: In long QT syndrome (LQTS), primary prevention improves outcome; thus, early identification is key. The most common LQTS phenotype is a foetal heart rate (FHR) < 3rd percentile for gestational age (GA) but the effects of cohort, genotype, variant, and maternal ß-blocker therapy on FHR are unknown. We assessed the influence of these factors on FHR in pregnancies with familial LQTS and developed a FHR/GA threshold for LQTS. METHODS AND RESULTS: In an international cohort of pregnancies in which one parent had LQTS, LQTS genotype, familial variant, and maternal ß-blocker effects on FHR were assessed. We developed a testing algorithm for LQTS using FHR and GA as continuous predictors. Data included 1966 FHRs at 7-42 weeks' GA from 267 pregnancies/164 LQTS families [220 LQTS type 1 (LQT1), 35 LQTS type 2 (LQT2), and 12 LQTS type 3 (LQT3)]. The FHRs were significantly lower in LQT1 and LQT2 but not LQT3 or LQTS negative. The LQT1 variants with non-nonsense and severe function loss (current density or ß-adrenergic response) had lower FHR. Maternal ß-blockers potentiated bradycardia in LQT1 and LQT2 but did not affect FHR in LQTS negative. A FHR/GA threshold predicted LQT1 and LQT2 with 74.9% accuracy, 71% sensitivity, and 81% specificity. CONCLUSION: Genotype, LQT1 variant, and maternal ß-blocker therapy affect FHR. A predictive threshold of FHR/GA significantly improves the accuracy, sensitivity, and specificity for LQT1 and LQT2, above the infant's a priori 50% probability. We speculate this model may be useful in screening for LQTS in perinatal subjects without a known LQTS family history.


Assuntos
Frequência Cardíaca Fetal , Síndrome do QT Longo , Lactente , Feminino , Gravidez , Humanos , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/genética , Genótipo , Antagonistas Adrenérgicos beta/efeitos adversos , Fenótipo , Eletrocardiografia
8.
Am J Obstet Gynecol ; 2023 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-37717890

RESUMO

BACKGROUND: The 22q11.2 deletion syndrome is the most common microdeletion syndrome and is frequently associated with congenital heart disease. Prenatal diagnosis of 22q11.2 deletion syndrome is increasingly offered. It is unknown whether there is a clinical benefit to prenatal detection as compared with postnatal diagnosis. OBJECTIVE: This study aimed to determine differences in perinatal and infant outcomes between patients with prenatal and postnatal diagnosis of 22q11.2 deletion syndrome. STUDY DESIGN: This was a retrospective cohort study across multiple international centers (30 sites, 4 continents) from 2006 to 2019. Participants were fetuses, neonates, or infants with a genetic diagnosis of 22q11.2 deletion syndrome by 1 year of age with or without congenital heart disease; those with prenatal diagnosis or suspicion (suggestive ultrasound findings and/or high-risk cell-free fetal DNA screen for 22q11.2 deletion syndrome with postnatal confirmation) were compared with those with postnatal diagnosis. Perinatal management, cardiac and noncardiac morbidity, and mortality by 1 year were assessed. Outcomes were adjusted for presence of critical congenital heart disease, gestational age at birth, and site. RESULTS: A total of 625 fetuses, neonates, or infants with 22q11.2 deletion syndrome (53.4% male) were included: 259 fetuses were prenatally diagnosed (156 [60.2%] were live-born) and 122 neonates were prenatally suspected with postnatal confirmation, whereas 244 infants were postnatally diagnosed. In the live-born cohort (n=522), 1-year mortality was 5.9%, which did not differ between groups but differed by the presence of critical congenital heart disease (hazard ratio, 4.18; 95% confidence interval, 1.56-11.18; P<.001) and gestational age at birth (hazard ratio, 0.78 per week; 95% confidence interval, 0.69-0.89; P<.001). Adjusting for critical congenital heart disease and gestational age at birth, the prenatal cohort was less likely to deliver at a local community hospital (5.1% vs 38.2%; odds ratio, 0.11; 95% confidence interval, 0.06-0.23; P<.001), experience neonatal cardiac decompensation (1.3% vs 5.0%; odds ratio, 0.11; 95% confidence interval, 0.03-0.49; P=.004), or have failure to thrive by 1 year (43.4% vs 50.3%; odds ratio, 0.58; 95% confidence interval, 0.36-0.91; P=.019). CONCLUSION: Prenatal detection of 22q11.2 deletion syndrome was associated with improved delivery management and less cardiac and noncardiac morbidity, but not mortality, compared with postnatal detection.

9.
Eur Heart J ; 44(35): 3357-3370, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37528649

RESUMO

AIMS: Calmodulinopathy due to mutations in any of the three CALM genes (CALM1-3) causes life-threatening arrhythmia syndromes, especially in young individuals. The International Calmodulinopathy Registry (ICalmR) aims to define and link the increasing complexity of the clinical presentation to the underlying molecular mechanisms. METHODS AND RESULTS: The ICalmR is an international, collaborative, observational study, assembling and analysing clinical and genetic data on CALM-positive patients. The ICalmR has enrolled 140 subjects (median age 10.8 years [interquartile range 5-19]), 97 index cases and 43 family members. CALM-LQTS and CALM-CPVT are the prevalent phenotypes. Primary neurological manifestations, unrelated to post-anoxic sequelae, manifested in 20 patients. Calmodulinopathy remains associated with a high arrhythmic event rate (symptomatic patients, n = 103, 74%). However, compared with the original 2019 cohort, there was a reduced frequency and severity of all cardiac events (61% vs. 85%; P = .001) and sudden death (9% vs. 27%; P = .008). Data on therapy do not allow definitive recommendations. Cardiac structural abnormalities, either cardiomyopathy or congenital heart defects, are present in 30% of patients, mainly CALM-LQTS, and lethal cases of heart failure have occurred. The number of familial cases and of families with strikingly different phenotypes is increasing. CONCLUSION: Calmodulinopathy has pleiotropic presentations, from channelopathy to syndromic forms. Clinical severity ranges from the early onset of life-threatening arrhythmias to the absence of symptoms, and the percentage of milder and familial forms is increasing. There are no hard data to guide therapy, and current management includes pharmacological and surgical antiadrenergic interventions with sodium channel blockers often accompanied by an implantable cardioverter-defibrillator.


Assuntos
Calmodulina , Síndrome do QT Longo , Taquicardia Ventricular , Criança , Humanos , Calmodulina/genética , Morte Súbita Cardíaca/etiologia , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , Mutação/genética , Sistema de Registros , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/genética
11.
J Clin Med ; 12(13)2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37445499

RESUMO

BACKGROUND: Repeated fetal heart rates (FHR) < 3rd percentile for gestational age (GA) with 1:1 atrioventricular conduction (sinus bradycardia) can be a marker for long QT syndrome. We hypothesized that other inherited arrhythmia syndromes might present with fetal sinus bradycardia. METHODS: We reviewed pregnancies referred with sinus bradycardia to the Colorado Fetal Care Center between 2013 and 2023. FHR/GA data, family history, medication exposure, normalized isovolumic contraction times (n-IVRT), postnatal genetic testing, and ECGs at 4-6 weeks after birth were reviewed. RESULTS: Twenty-nine bradycardic subjects were evaluated by fetal echocardiography. Five were lost to follow-up, one refused genetic testing, and one had negative genetic testing for any inherited arrhythmia. Six had non-genetic causes of fetal bradycardia with normal prenatal n-IVRT and postnatal QTc. Thirteen carried pathogenic variants in RYR2 (n = 2), HCN4 (n = 2), KCNQ1 (6), and other LQTS genes (n = 4). The postnatal QTc was <470 ms in subjects with RYR2, HCN4, and two of those with KCNQ1 mutations, and >470 ms in subjects with CALM 2, KCNH2, SCN5A, and four of those with KCNQ1 mutations. LQTS and RYR2 mutations were associated with prolonged n-IVRT, but HCN4 was not. Two fetuses died in utero with variants of uncertain significance (CACNA1 and KCNE1). Cascade testing uncovered six affected but undiagnosed parents and confirmed familial inheritance in five. CONCLUSION: In addition to heralding LQTS, repeated FHR < 3rd percentile for GA is a risk factor for other inherited arrhythmia syndromes. These findings suggest that genetic testing should be offered to infants with a history of FHR < 3rd percentile for GA even if the postnatal ECG demonstrates a normal QTc interval.

13.
Front Immunol ; 14: 1114808, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37090702

RESUMO

Background: Fibrosis and dystrophic calcification disrupting conduction tissue architecture are histopathological lesions characterizing cardiac manifestations of neonatal lupus (cardiac-NL) associated with maternal anti-SSA/Ro antibodies. Objectives: Increased appreciation of heterogeneity in fibroblasts encourages re-examination of existing models with the consideration of multiple fibroblast subtypes (and their unique functional differences) in mind. This study addressed fibroblast heterogeneity by examining expression of α-Smooth Muscle Actin (myofibroblasts) and of S100 Calcium-Binding Protein A4 (S100A4). Methods: Using a previously established model of rheumatic scarring/fibrosis in vitro, supported by the evaluation of cord blood from cardiac-NL neonates and their healthy (anti-SSA/Ro-exposed) counterparts, and autopsy tissue from fetuses dying with cardiac-NL, the current study was initiated to more clearly define and distinguish the S100A4-positive fibroblast in the fetal cardiac environment. Results: S100A4 immunostaining was observed in 4 cardiac-NL hearts with positional identity in the conduction system at regions of dystrophic calcification but not fibrotic zones, the latter containing only myofibroblasts. In vitro, fibroblasts cultured with supernatants of macrophages transfected with hY3 (noncoding ssRNA) differentiated into myofibroblasts or S100A4+ fibroblasts. Myofibroblasts expressed collagen while S100A4+ fibroblasts expressed pro-angiogenic cytokines and proteases that degrade collagen. Cord blood levels of S100A4 in anti-SSA/Ro-exposed neonates tracked disease severity and, in discordant twins, distinguished affected from unaffected. Conclusions: These findings position the S100A4+ fibroblast alongside the canonical myofibroblast in the pathogenesis of cardiac-NL. Neonatal S100A4 levels support a novel biomarker of poor prognosis.


Assuntos
Calcinose , Bloqueio Cardíaco , Recém-Nascido , Humanos , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/patologia , Coração , Biomarcadores , Fibrose , Fibroblastos/metabolismo , Proteína A4 de Ligação a Cálcio da Família S100/metabolismo
14.
Echocardiography ; 40(3): 204-216, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36734058

RESUMO

INTRODUCTION: Speckle tracking analysis was used to evaluate right (RA) and left (LA) atria size, shape and contractility to create a probability calculator to identify fetuses at risk for urgent neonatal balloon atrial septostomy (BAS). METHODS: The study group consisted of 39 fetuses with D-TGA, of which 55% (N = 22) required neonatal BAS and 45% (N = 17) did not. The RA and LA end-diastolic areas, lengths, widths, and sphericity indices as well as global, longitudinal, and transverse contractility were measured with speckle tracking analysis. The z-scores of the measurements were compared to 200 controls. Logistic regression analysis of the computed z-score measurements was performed to separate fetuses requiring urgent neonatal atrial BAS from those who did not. RESULTS: The following z-score values for all fetuses with D-TGA, irrespective of whether they required neonatal BAS, that were significantly less than controls: RA base sphericity index, basal-apical length fractional shortening, fractional area change, lateral wall annular plane systolic excursion (APSE), and longitudinal reservoir strain; LA mid-chamber width, fractional shortening, ejection fraction, basal-apical length fractional shortening, atrial ejection volume, septal wall APSE, and reservoir strain. The following z-score values were significantly larger than control values: RA/LA mid-chamber width, RA/LA base width, and RA mid-chamber length. Logistic regression analysis identified the following five measurements that correctly identified 19 of 22 fetuses requiring urgent neonatal atrial BAS with a sensitivity of 86.4%, a false-positive rate of 11.8% and a positive predictive value of 90.4%: (1) LA mid-chamber transverse fractional shortening, (2) RA mid-chamber end-diastolic width, (3) RA basal-apical length fractional shortening, (4) RA mid-chamber fractional shortening, and (5) RA fractional area change. CONCLUSION: Using the measurements described in this study identified significant differences between all fetuses with D-TGA and controls, as well as identified measurements that predicted the probability of D-TGA fetuses requiring neonatal septostomy.


Assuntos
Fibrilação Atrial , Transposição dos Grandes Vasos , Recém-Nascido , Feminino , Gravidez , Humanos , Ecocardiografia , Ultrassonografia Pré-Natal , Coração Fetal/diagnóstico por imagem , Artérias
15.
Pediatr Cardiol ; 44(6): 1382-1396, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36853336

RESUMO

INTRODUCTION: Speckle tracking analysis of the endocardium of the right (RV) and left (LV) ventricles was used to evaluate the size, shape, and contractility of these chambers in fetuses with D-Transposition of the great arteries (D-TGA) to identify fetuses that would require emergent balloon atrial septostomy (BAS) after birth. METHODS: This was a retrospective analysis of fetuses with D-TGA and intact ventricular septum that were divided into 2 groups. Group 1 underwent urgent BAS after birth because of a restrictive atrial septum and group 2 did not. Using speckle tracking analysis, the end-diastolic and end-systolic RV and LV areas, lengths, widths, sphericity indices, and contractility were computed. Logistic regression analysis was performed to identify fetuses who would require urgent neonatal BAS. RESULTS: Of the 39 fetuses with D-TGA, 55% (n = 22) required urgent neonatal BAS (group 1) and 45% (n = 17) (group 2) did not. When comparing D-TGA groups 1 and 2, differences were seen in RV and LV area, sphericity index for segment 1 of the LV, LV fractional area of change and free wall annular plane systolic excursion, fractional shortening for LV segment 12, and RV free wall strain. Regression analysis of these measurements identified 91% of neonates who underwent BAS, with a false-positive rate of 12%. CONCLUSION: Using speckle tracking analysis to evaluate the RV and LV, measurable differences were identified for the RV and LV size, shape, and contractility between fetuses who underwent neonatal urgent BAS vs. those who did not require this procedure.


Assuntos
Fibrilação Atrial , Transposição dos Grandes Vasos , Recém-Nascido , Humanos , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Ecocardiografia/métodos , Estudos Retrospectivos , Ventrículos do Coração/diagnóstico por imagem , Coração Fetal/diagnóstico por imagem , Coração Fetal/cirurgia
16.
Prenat Diagn ; 43(4): 544-552, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36759743

RESUMO

INTRODUCTION: Whole exome sequencing (WES) has increasingly become integrated into prenatal care and genetic testing pathways. Current studies of prenatal WES have focused on diagnostic yield. The possibility of obtaining a variant of uncertain significance and lack of provider expertise are frequently described as common barriers to clinical integration of prenatal WES. We describe the implementation and workflow for a multidisciplinary approach to effectively integrate prenatal WES into maternal-fetal care to overcome these barriers. METHODS: A multidisciplinary team reviews and approves potential cases for WES. This team reviews WES results, reclassifying variants as appropriate and provides recommendations for postnatal care. A detailed description of this workflow is provided, and a case example is included to demonstrate effectiveness of this approach. Our team has approved 62 cases for WES with 45 patients ultimately pursuing WES. We have achieved a diagnostic yield of 40% and the multidisciplinary team has played a role in variant interpretation in 50% of the reported variants of uncertain significance. CONCLUSIONS: This approach facilitates communication between prenatal and postnatal care teams and provides accurate interpretation and recommendations for identified fetal variants. This model can be replicated to ensure appropriate patient care and effective integration of novel genomic technologies into prenatal settings.


Assuntos
Feto , Cuidado Pré-Natal , Gravidez , Feminino , Humanos , Sequenciamento do Exoma , Fluxo de Trabalho , Testes Genéticos
17.
J Ultrasound Med ; 42(3): 637-646, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35822424

RESUMO

OBJECTIVES: The prenatal detection of D-Transposition of the great arteries (D-TGA) and tetralogy of Fallot (TOF) has been reported to be less than 50% to as high as 77% when adding the outflow tracts to the four-chamber screening protocol. Because many examiners still struggle with the outflow tract examination, this study evaluated whether changes in the size and shape of the heart in the 4CV as well as the ventricles occurred in fetuses with D-TGA and TOF could be used to screen for these malformations. METHODS: Forty-four fetuses with the pre-and post-natal diagnosis of D-TGA and 44 with TOF were evaluated between 19 and 36 weeks of gestation in which the 4CV was imaged. Measurements of the end-diastolic width, length, area, and global sphericity index were measured for the four-chamber view and the right and left ventricles. Using z-score computed values, logistic regression was performed between the 88 study and 200 control fetuses using the hierarchical forward selection protocol. RESULTS: Logistic regression identified 10 variables that correctly classified 83/88 of fetuses with TOF and TGA, for a sensitivity of 94%. Six of 200 normal controls were incorrectly classified for a false-positive rate of 3%. The area under the receiver operator classification curve was 98.1%. The true positive rate for D-TGA was 93.2%, with a false-negative rate to 6.8%. The true positive rate for TOF was 95.5%, with a false negative rate of 4.5%. CONCLUSIONS: Measurements of the 4CV and of the RV and LV may help identify fetuses at risk for D-TGA or TOF.


Assuntos
Tetralogia de Fallot , Transposição dos Grandes Vasos , Gravidez , Feminino , Humanos , Transposição dos Grandes Vasos/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Tetralogia de Fallot/diagnóstico por imagem , Ecocardiografia/métodos , Artérias , Feto , Ultrassonografia Pré-Natal/métodos
18.
Am J Obstet Gynecol ; 227(5): 761.e1-761.e10, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35690080

RESUMO

BACKGROUND: The risk of fetal atrioventricular block in anti-Ro/SSA antibody-exposed pregnancies with no previous affected offspring is approximately 2%. A high antibody titer is necessary but not sufficient for atrioventricular block, and specific antibody titers do not predict risk. However, there are no data on the negative predictive value of antibody titer to identify pregnancies at low risk of fetal atrioventricular block, and may not require surveillance. OBJECTIVE: This study aimed to define anti-Ro52 and anti-Ro60 antibody thresholds for the identification of fetuses unlikely to develop atrioventricular block using clinically validated and research laboratory tests. STUDY DESIGN: This study performed a multicenter review of pregnant subjects who tested positive in their local commercial laboratories for anti-Ro/SSA antibodies at the University of Colorado Children's Hospital (2014-2021) and Phoenix Children's Hospital (2014-2021) and enrolled in the Research Registry for Neonatal Lupus (RRNL) at New York University Langone Medical Center (2002-2021). The subjects were referred on the basis of rheumatologic symptoms or history of atrioventricular block in a previous pregnancy and were retrospectively grouped on the basis of pregnancy outcome. Group 1 indicated no fetal atrioventricular block in current or past pregnancies; group 2 indicated fetal atrioventricular block in the current pregnancy; and group 3 indicated normal current pregnancy but with fetal atrioventricular block in a previous pregnancy. Maternal sera were analyzed for anti-Ro52 and anti-Ro60 antibodies using a clinically validated multiplex bead assay (Associated Regional and University Pathologists Laboratories, Salt Lake City, UT) and a research enzyme-linked immunosorbent immunoassay (New York University). This study calculated the negative predictive value separately for anti-Ro52 and anti-Ro60 antibodies and for the 2 combined using a logistic regression model and a parallel testing strategy. RESULTS: This study recruited 270 subjects (141 in group 1, 66 in group 2, and 63 in group 3). Of note, 89 subjects in group 1 had data on hydroxychloroquine treatment: anti-Ro/SSA antibody titers were no different between those treated (n=46) and untreated (n=43). Mean anti-Ro52 and anti-Ro60 titers were the lowest in group 1 and not different between groups 2 and 3. No case of fetal atrioventricular block developed among subjects with anti-Ro52 and anti-Ro60 titers of <110 arbitrary units per milliliter using the multiplex bead assay of the Associated Regional and University Pathologists Laboratories (n=141). No case of fetal atrioventricular block developed among subjects with research laboratory anti-Ro52 titers of <650 and anti-Ro60 of <4060 enzyme-linked immunosorbent immunoassay units (n=94). Using these 100% negative predictive value thresholds, more than 50% of the anti-Ro/SSA antibody pregnancies that ultimately had no fetal atrioventricular block could be excluded from surveillance based on clinical and research titers, respectively. CONCLUSION: Study data suggested that there is a clinical immunoassay level of maternal anti-Ro/SSA antibodies below which the pregnancy is at low risk of fetal atrioventricular block. This study speculated that prospectively applying these data may avert the costly serial echocardiograms currently recommended for all anti-Ro/SSA-antibody positive pregnancies and guide future management.

20.
Semin Perinatol ; 46(4): 151585, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35410713

RESUMO

Approximately one percent of pregnant women will produce anti-Sjogren's syndrome-related antigen A (anti-Ro/SSA) antibodies. Of these pregnancies, one to three percent will have a fetus that develops atrioventricular (AV) block. Earlier stages of AV block (1° or 2°) may respond to anti-inflammatory treatment, but complete (3°) AV block, which can occur within 24 hours of a normal fetal rhythm, is likely irreversible and carries substantial risk for significant morbidity and for mortality. Emerging data has shown that ambulatory fetal heart rhythm monitoring can detect the transition period from normal rhythm to 2° AV block, the time during which treatment with IVIG and dexamethasone can potentially restore normal sinus rhythm. Weekly or biweekly fetal echocardiograms occur too infrequently to detect this transition period but may still be useful in diagnosing extranodal anti-Ro antibody mediated cardiac disease. In this review, we evaluate the most innovative methods for surveillance and treatment of this disease.


Assuntos
Bloqueio Atrioventricular , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Ecocardiografia , Feminino , Feto , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...